TensorGrip® LP61 is a Class O Fire Rated spray glue, suitable for bonding HPL, veneers and almost all other decorative face laminates to a variety of substrates including MDF, chipboard, plywood and many other timber sheet materials, as well as plastic, aluminium sheeting, and synthetic leathers. This unique formulation is designed for permanent and LIFETIME GUARANTEED bonding of materials where high grab and superior bond strength are required. LP61 contact adhesive can cover an area up to 75m2.

TensorGrip® LP61 is suitable for bonding HPL, veneers and almost all other decorative face laminates to a variety of substrates including MDF, chipboard, plywood and many other timber sheet materials, as well as plastic, aluminium sheeting, and synthetic leathers. This unique formulation is designed for permanent and LIFETIME GUARANTEED bonding of materials where high grab and superior bond strength are required.

LP61 Contact Spray Adhesive Benefits

  • CLASS-0 Fire Rating
  • Easy application control
  • Fast Flash off Time
  • Non-Chlorinated Adhesive – making this a healthy adhesive
  • High Temp Resistance – 128°C
  • Minimal Cleaning

Description

Tensorgrip LP61 Suitable For:

  • Aluminium Sheeting
  • Synthetic Leather
  • Standard Laminate
  • FRL
  • Plastic

Tensorgrip LP61 Properties:

  • Web Spray
  • Class-O Fire Rated
  • Open Time – Up to 40 mins
  • Colour – Orange
  • Application – 2 Sided
  • Flash Off – 1-3 mins

Tensorgrip LP61 Technical Information:

Viscosity 350 cps 25°C sp#2, 30r.p.m.
Total Solids 29%-31%
Colour Orange
System Flammability Non-flammable adhesive in flammable propellant
Shear > 250 p.s.i.
Tensile (180° Peel) > 25 p.s.i.
90° Peel (6.25 sq.cm) > 25 p.s.i.
Shear adhesion failure temp. (SAFT) 100gram > 128°C
Heat resistance (25mm/100gram) 115°C
Flash-off time 1-3 mins
Open time Up to 40 mins
SHELF LIFE 18 months from date of manufacture

Download Technical Data Sheet For Tensorgrip LP61:

TensorGrip-LP61-TDS.pdf

Directions For Use:

This product is designed to be applied to one side of the surfaces to be bonded together, However, It can be used for double sided bonding where required. Make sure that surfaces are clean, dry and free from dirt, dust, oil, loose paint, wax or grease, etc. For best results, the temperature of the adhesive and the surfaces being bonded should be between 60 degrees F – 80 degrees F (16degrees C – 27 degrees C).

Use with adequate ventilation. When possible we recommend shaking the canister well before using. Attach and secure hose tightly onto the spray gun with required tip. Attach the other end of the hose onto the canister. Make sure the hose-valve connections are securely tight. Open the valve on the canister slowly and fully, check for leaks during this process. Unlock the trigger on the spray gun to start spraying.

Prior to use, check compatibility by spraying a small test patch of the adhesive on the substrate. This product may degrade some substrates.

Make sure that surfaces are clean, dry and free from dirt, dust, oil, loose paint, wax or grease, etc.

Spray about 10-20 cm (4” – 8”) away at a 90 degree angle to the surface, applying a uniform, even coat of adhesive to obtain 80% to 100% coverage of the surface. If necessary, spray another coat of adhesive in areas that appear to need more adhesive.

Spray both surfaces to be bonded, one surface vertically and the other surface horizontally.

Allow 2 – 3 minutes for the adhesive to tack off until no adhesive transfers to the knuckle when touched.

Adhere surfaces and press together with adequate pressure. A roller is recommended to apply a uniform pressure to achieve maximum strength. Allow 24 hours for the adhesive to fully cure.

If the spray tip clogs, unscrew the spray tip from the gun and clean with solvent such as lacquer thinner or acetone. Do not use a pin on the spray tip orifice.

Handling & Storage:

Consult Material Safety Data Sheet prior to use.

DO NOT store at temperatures over 50°C.

Avoid exposure to direct sunlight.

DO NOT store directly on concrete floor.

For optimum performance, store at 18°C during use, but must always be above 10°C.

When connected, keep valve open and hose pressurised at all times.

DO NOT close valve until ready to connect to new cylinder.

Release pressure in hose before disconnection.

Always test product to determine suitability for your particular application prior to use in production.

MSDS and Technical Data Sheets MUST be read and understood before use. Information contained in this technical literature is believed to be accurate and offered in good faith for the benefit of the consumer. The company however cannot assume any liability or risk involved in the use of its chemical products since the conditions of use are beyond our control. Statements concerning the possible use of our products are not intended as recommendations to infringe on any patent. These products are for industrial use only.